Oxigraf O2iM NEMA 4X Oxygen Analyzer
February 13, 2007 08-0427-B0, Manual, O2iM.doc Page 26
Appendix A – Menu Structure
Key Function Display Line 1 Display Line 2
O2:
Display O2 and current channel
 
O2 Filter setpoint
 
Number of multipoint scan channels (H)
 
Scan time per channel (H)
  
O2 Measurement mode XC
!"# $%&
Low cal gas concentration
' (!"#
High cal gas concentration
)# !"#
Autocal period
*+,% +
Cal valve delay
-./" 
Autocal mode setup
*+$% 
Autocal O2 level trigger enable
*+'.0 11
4 mA O2 value
*+ !"#
20 mA O2 value
*+ !"#
Set O2 measurement mode
!"#( $%&
Flow setpoint
 
Pump On/Off/Max
 ,+
Low O2 limit A
'** (!"#
High O2 limit A
)#** 11
Low O2 limit B
'*0 11
High O2 limit B
)#*0 !"#
O2 limit hysteresis
*)" !"#
Low flow alarm
'* 2
Pump drive level alarm
,+/.* 11
Low pressure alarm
',* 3
High pressure alarm
)#,* 3
Relay latch mode
"' '*
Relay flash mode
" '0
Relay failsafe mode
"1 11
Relay exclusive mode
"4!+. 11
Relay normal/channel mode allocation
"* "56*0
Horn/Strobe mode control
)3 6#7*
Alarm delay
*/" 
Alarm acknowledge time
**8  
Mode idle dwell time
$%/  
Keypad beep volume
0-9:; 
Keypad Lock
5"%'8 2
Setup
Modbus enable address (H)
$%3+*%% 11
Display fault history memory
+$# 4< 4
Display cell pressure/temperature
,23 
Display laser temperature
'=2 '= 2
Reset Calibration Parameters
,4< 48" >
Restart O2iM software
,4< 48" >
Enter simulated O2 reading
!"#? +
Test
Ramp simulated O2 from 0 to 100%
!"#2@ +
Cal 1
Cal 1 O2, execute with Enter key
!"#( '(
Setup
Low cal gas concentration
' (!"#
Setup
Continue with normal setup menu...
Cal 2
Cal 2 O2, execute with Enter key
!"#(? )#
Setup
High cal gas concentration
)# !"#
Setup
Continue with normal setup menu...
Flow
Display sample flow and pressure Flow: 150 ml/m
,23
Setup
Flow setpoint Flow Setpoint
