Front panel 5
1 2 3 4
6
9
5
13
16
7
10
8
14
15
17
12
11
1 [ALM] indicator This is the camera and CCU warning indicator lamp.
Consult your dealer if a failure occurs.
The indicator's color changes to indicate when the camera and CCU optical reception level is
not strong enough, when a data error has occurred in the CCU optical transmission/reception
section, and when a fan error or temperature error has been occurred on the camera or CCU.
2 [OPT] indicator This is the camera cable warning indicator lamp.
Status displays
Lit orange: Warns that an optical transmission error has occurred.
Lit red: Indicates that the camera is not connected to the CCU.
Off: The camera cable is connected normally.
3 [EXT] indicator This indicator lights to warn that the lens extender is set to something other than 1x.
Status displays
On: The lens extender is set to something other than 1x.
Off: This indicates that the lens extender is not being used or that it is not available.
4 [D.EXT] indicator This indicator lights to warn that the digital extender is set to something other than 1x.
Status displays
On: The digital extender is set to something other than 1x.
Off: This indicates that the digital extender is not being used or that it is not available.
5 Adjustment value display Displays the ND filter, CC filter, iris, master gain, master pedestal, shutter, or sync shutter
adjustment value based on the item selected with the [DISP] button.
6 [ND] indicator Lights when the ND filter is selected with the [DISP] button.
Status displays
Lit green: Standard position set in the ROP menu.
Lit orange: Updated from the standard position set in the ROP menu.
n The standard position of the ND filter can be set in [ROP SETTING] > [STD POSITION
ND] in the ROP menu.
“STD POSITION ND” (see page 113)
7 [CC] indicator Lights when the CC filter is selected with the [DISP] button.
Status displays
Lit green: Standard position set in the ROP menu.
Lit orange: Updated from the standard position set in the ROP menu.
n The standard position of the CC filter can be set in [ROP SETTING] > [STD POSITION
CC] in the ROP menu.
“STD POSITION CC” (see page 113)
- 29 -