44
No.
Function
name
Changes
during RUN
Setting range Unit
Initial
value
P062
Torque
Boost
Amplitude
0 to 200 1[%] *4
P063
Torque
Boost
Reply
Amplitude
0 to 200 1[%] *4
P064
Internal
component
cooling fan
ON-OFF
control
selection
0: ON – when Run command is ON
OFF – when Run command is OFF
(FAn2 Trip Yes)
1: ON – when Run command is ON and internal
temperature is 40 or above
OFF – when Run command is OFF and internal
temperature is 30 or below (or power is turned
off)
(FAn2 Trip Yes)
2: ON – when Run command is ON
OFF – when Run command is OFF
(FAn2 Trip No/Alarm goes off)
3: ON – when Run command is ON and internal
temperature is 40 or above
OFF – when Run command is OFF or internal
temperature is 30 or below (or power is turned
off)
(FAn2 Trip No/Alarm goes off)
3