43
No.
Function
name
Changes
during RUN
Setting range Unit
Initial
value
P050
3rd Skip
Frequency
0.0 · 0.2 to 400.0 0.1[Hz] 0.0
P051
Skip
Frequency
Bandwidth
0 to 10 1[Hz] 0
P052
Cooling
Fan ON-
OFF
Control
Selection
0: ON during power-on/OFF during power-off (with
fan trip)
1: ON during power-on/OFF when internal module
temperature below 100
(with fan trip)
2: ON during power-on/OFF during power-off
(without fan trip/with alarm)
3: ON during power-on/OFF when internal module
temperature below 100
(without fan trip/with alarm)
0
P053
Input
Terminal
Filter
5 to 100
1[times]
20
P054
Linear
Speed
Multiplier
0.1 to 100.0
1
[Multiplier]
3.0
P055
Setting
Data Clear
0: Normal condition
1: Restore all tha data (motor constant excluded)
to factory settings.
2: Restore all the data to factory settings.
0
P056
Alarm LED
Operation
Selection
0: No setting
1: Full monitor alarm
2: Output voltage
3: Overload
4: Abnormal temperature
5: Timer operation stop
6: Abnormal cooling fan
0
P057
Upper
Voltage
Limit of
Alarm LED
0.1 to 600.0 0.1[V] *5
P058
Upper
Current
Limit of
Alarm LED
0.1 to 100.0 0.1[A] *4
P059 Password 0000 to 9999 0000
P060
MOP
Operation
Selection
0: MOP operation linked with acceleration/
deceleration time
1: MOP operation linked with frequency setting
2: MOP function disabled
2
P061
Acceleration/
Deceleration
Time for
MOP
Operation
0.04 to 3600
0.01
[sec]*9
*4