(4) Replacement of the bin unit (FA-S660) (continued)
Disconnect the sensor harness.
(2 Connectors, 1 Tie wrap)
9
Remove the sensor harness as shown.
10
11
Remove the guide bar holder (upper).
(2 screws)
12
Remove the bin lower unit.
Note:
Pull out the guide bar holder separating
it from the guide bar.
13
Remove the bins removing the bin roll
stoppers.
Tie wrap Sensor harness
Connector
Sensor
harness
Screw
Guide bar holder
cupper
Screw
Screw
Bin
lower unit
1