36
KX-FLB802CX/KX-FLB812CX/KX-FLB802CXS/KX-FLB812CXS
<Stop operation>
In order to stop the motor rotation, following 2 signals are supplied from IC604.
1. SS signal
Output pin: Pin 120/Output Signal: “L”
Consequently “Start/Stop” signal becomes “H”.
2. Break signal
Output pin: Pin 122/Output Signal: “H”
Motor stops rapidly by changing the “Break” signal from “L” to “H”.
Timing Chart of Stop operation
6.8.1.1. ENGINE MOTOR DRIVE CIRCUIT