7
KX-FLB802CX/KX-FLB812CX/KX-FLB802CXS/KX-FLB812CXS
2.2. INSULATION RESISTANCE TEST
1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with an ohmmeter between the jumpered AC plug and each exposed metal cabinet part
(screw heads, control shafts, bottom frame, etc.).
Note: Some exposed parts may be isolated from the chassis by design. These will read infinity.
4. If the measurement is outside the specified limits, there is a possibility of a shock hazard.
2.3. BATTERY CAUTION
CAUTION
Danger of explosion if the battery is replaced incorrectly. Replace only with the same or equivalent type recommended by the
manufacturer. Dispose used batteries according to the manufacturer’s instructions:
The lithium battery is a critical component (type No.CR2032). Please observe for the proper polarity and exact location when
replacing it and the soldering the replacement litium battery in