Default Value
N
PERIODIC_INFORM_INTERVAL
Value Format INTEGER
Description Specifies the interval length, in seconds, when the CPE must attempt
to connect with the ACS and call the Inform method.
Note
This setting is available only when
"PERIODIC_INFORM_ENABLE" is set to "Y".
Value Range 30–2419200
Default Value 86400
PERIODIC_INFORM_TIME
Value Format STRING
Description Specifies the time (UTC) to determine when the CPE will initiate the
periodic Inform method calls.
Note
Each Inform call must occur at this reference time plus or
minus an integer multiple of the
"PERIODIC_INFORM_INTERVAL". This
"PERIODIC_INFORM_TIME" parameter is used only to set the
"phase" of the periodic Informs. The actual value can be
arbitrarily set far into the past or future.
For example, if "PERIODIC_INFORM_INTERVAL" is set to
86400 (one day) and if "PERIODIC_INFORM_TIME" is set to
midnight on a certain day, then periodic Informs will occur
every day at midnight, starting from the set date.
If the time is set to "unknown time", the start time depends on
the CPE’s settings. However, the
"PERIODIC_INFORM_INTERVAL" must still be adhered to.
If absolute time is not available to the CPE, its periodic Inform
behavior must be the same as if the
"PERIODIC_INFORM_TIME" parameter was set to the
"unknown time".
Time zones other than UTC are not supported.
Value Range 4–32 characters
date and time format
Default Value 0001-01-01T00:00:00Z
CON_REQ_USER_ID
Value Format STRING
Description Specifies the user name used to authenticate an ACS making a
Connection Request to the CPE.
Value Range Max. 256 characters
5.3.9 TR-069 Settings
228 Administrator Guide Document Version: 2017-07