Error Code Error Message PROBABLE CAUSE SOLUTION
219 PT I/F error
·
Optional service card malfunction:
DHLC, DLC
·
Software error due to external
factors
·
Breaking of telephone
cord/interference of noise
·
See if the corresponding optional service card is installed
properly
·
Pull out and re-insert the corresponding optional service
card
·
Press the Reset Button
·
Check the wiring
·
Replace the corresponding optional service card
System Start-up and On-line Operation
Error Code Error Message PROBABLE CAUSE SOLUTION
000* MPR WDT overflow
·
MPR card malfunction
·
Erroneous processing of MPR card
software
·
Software error due to external
factors
·
Press the Reset Button
·
Reprogram the main unit (Hybrid IP-PBX)
·
Replace the MPR card (be sure to turn off the main unit
(Hybrid IP-PBX) when replacing)
001 SDRAM bit error
002 System Reset
·
Reset Button is pressed
·
Power failure
·
MPR card malfunction
·
Erroneous processing of MPR card
software
·
Software error due to external
factors
·
Ignore if not frequent
·
Press the Reset Button
·
Reprogram the main unit (Hybrid IP-PBX)
·
Replace the MPR card (be sure to turn off the main unit
(Hybrid IP-PBX) when replacing)
010* AC power down
·
Power supply system malfunction
(e.g., power failure, power noise,
trouble with UPS)
·
Bad connection or breaking of AC
cord
·
Power supply circuit (PSU, back
board) malfunction
·
Check the power supply system
·
See if the AC cord is connected properly
·
Check the AC cord
·
Replace the AC cord (be sure to turn off the main unit
(Hybrid IP-PBX) when replacing)
·
Replace the PSU (be sure to turn off the main unit (Hybrid
IP-PBX) when replacing)
·
Replace the back board (be sure to turn off the main unit
(Hybrid IP-PBX) when replacing)
011* DC power down
·
AC power down
·
Power supply circuit (PSU, back
board) malfunction
·
Detection of over current (short
circuit on optional service cards)
·
Check the power supply system
·
See if the AC cord is connected properly
·
Check the AC cord
·
Replace the AC cord (be sure to turn off the main unit
(Hybrid IP-PBX) when replacing)
·
Replace the PSU (be sure to turn off the main unit (Hybrid
IP-PBX) when replacing)
·
Replace the back board (be sure to turn off the main unit
(Hybrid IP-PBX) when replacing)
·
Remove the optional service cards and restart the main unit
(Hybrid IP-PBX)
012* MPR RAM battery low
·
Battery out
·
MPR card malfunction
·
Replace the MPR card (be sure to turn off the main unit
(Hybrid IP-PBX) when replacing)
014* FAN Alarm
·
PSU-L malfunction
·
See if anything is jammed in the fan
·
Replace the PSU (be sure to turn off the main unit (Hybrid
IP-PBX) when replacing)
016 CS overload
·
Defective cable
·
CS malfunction
·
Optional service card malfunction:
CSIF
·
Check the cable diameter and length
·
Replace the CS
·
Replace the corresponding optional service card
018 CS superframe
synchronization failure
·
Optional service card malfunction:
CSIF
·
Replace the corresponding optional service card
020* SD file access error
·
SD Memory Card malfunction
·
Bad connection of SD Memory
Card
·
MPR card malfunction
·
Press the Reset Button
·
Reprogram the main unit (Hybrid IP-PBX)
·
Replace the SD Memory Card
·
Replace the MPR card (be sure to turn off the main unit
(Hybrid IP-PBX) when replacing)
021* SD Memory Card
disconnected
·
SD Memory Card not installed
·
Bad connection of SD Memory
Card
·
SD Memory Card malfunction
·
MPR card malfunction
52
KX-TDA200BX