6.6 Removal of B/Q-Module
TOP PREVIOUS NEXT
1. Remove the upper case according to the section 6.2. "Removal of Upper Case".
2. Unscrew the 2 screws and remove the S-P.C.Board.
3. Unhook the hook section and remove the duct cover.
4. Unscrew the 1 screw and remove the ground fittings.
5. Unscrew the 1 screw and release the ballast block.
6. Unscrew the 2 screws and remove the power box with power shield plate.
7. Unscrew the 2 screws and release the lamp unit terminal.
8. Disconnect the connector P2 and remove the ballast block.
9. While sliding the ballast grounding metal, unhook the hook section and remove it.