6.17 Replacement of Incidence Polarizer (R and
B)
TOP PREVIOUS NEXT
1. Remove the A-P.C.Board block according to the steps 1 through 3 in the section 6.3.
"Removal of A-P.C.Board".
2. Unscrew the 2 screws and release the lamp unit terminal.
3. Unscrew the 1 screw and remove the thermofuse attachment.
4. Unscrew the 3 screws and remove the lamphouse.
5. Unscrew the 2 screws and remove the LCD block.
6. Unscrew the 2 screws and remove the analysis case (upper) while expanding the hook of it
outside.
Notes:
❍ Because the hook is damaged easily, be careful not to expand it excessively.
❍ The incidence polarizer (G) is installed in the analysis case (upper). Handle it with
care.