6.10 Removal of Analysis Block and Projection
Lens
TOP PREVIOUS NEXT
1. Remove the lamp unit according to the section 6.9. "Removal of Lamp Unit".
2. Remove the A-P.C.Board block according to the steps 1 through 3 in the section 6.3.
"Removal of A-P.C.Board".
3. Unscrew the 2 screws and release the lamp unit terminal.
4. Unscrew the 1 screw and remove the thermofuse attachment.
5. Unscrew the 3 screws and remove the lamphouse.
6. Unscrew the 3 screws and remove the block of Analysis Block, LCD Block and Projection
Lens Block.
7. Unscrew the 2 screws and remove the LCD block.