Chapter 6Maintenance — [SELF TEST] indications
190 - ENGLISH
Error/warning display Details Action number
FE9 Exhaust fan 2 error 5
FF0 Radiator fan 2 error 5
FF1 Radiator fan 1 error 5
FF2 Prism fan error 5
FH0
Phosphor wheel 1 error
5
FH1 5
FH2
Phosphor wheel 2 error
5
FH3 5
FJ0 Liquid cooling pump 1 error 5
FJ1 Liquid cooling pump 2 error 5
FL1 Light source 1 unit error 6
FL2 Light source 2 unit error 6
Note
f The self-diagnosis display and the details of the malfunction may be different.
f For errors and warnings that are not described in the table, consult your dealer.
r Measure for error and warning
Action
number
Measure
1 The operating environment temperature is too high. Use the projector in an appropriate operating environment temperature
*1
.
2 The operating environment temperature is too low. Use the projector in an appropriate operating environment temperature
*1
.
3 The input supply voltage is low. Use electric wiring that can sufciently withstand the power consumption of the projector.
4 Battery replacement is required. Consult your dealer.
5 If the display does not clear after switching the main power off and on, consult your dealer.
6
The light source has failed to turn on. If the light source does not light up after turning the power off and on, consult your
dealer.
*1 For details of operating environment temperature of the projector, refer to “Operating environment temperature” (x page 213).