Chapter 7 Appendix — Technical information
196 - ENGLISH
r GEOMETRY
Performance Parameter Default value
OFF 0-15
255
KEYSTONE 16-31
CURVED CORRECTION 32-47
PC-1 48-63
PC-2 64-79
PC-3 80-95
CORNER CORRECTION 96-111
No operation 112-255
r CUSTOM MASKING
To use PC-1, PC-2, or PC-3, the optional Upgrade Kit (Model No.: ET-UK20) is required.
Performance Parameter Default value
OFF 0-31
255
PC-1 32-63
PC-2 64-95
PC-3 96-127
No operation 128-255
r FREEZE
Performance Parameter Default value
No operation 0-31
128
OFF 32-95
No operation 96-159
ON 160-223
No operation 224-255
r COLOR, TINT
Performance Parameter Default value
No operation 0-31
0
Factory default setting 32-63
-
31 64-65
… …
0 128-129
… …
+31 190-191
No operation 192-255
r RASTER PATTERN
Performance Parameter Default value
No operation 0-15
0
OFF 16-31
WHITE 32-47
YELLOW 48-63
CYAN 64-79
GREEN 80-95
MAGENTA 96-111
RED 112-127
BLUE 128-143
BLACK 144-159
USER LOGO 160-175
No operation 176-255