11 Service Position
Note: For description of the disassembly procedures, see the Section 10
11.1. Checking & Repairing of SMPS
P.C.B.
Step 1 : Remove the Base Stand Assembly.
Step 2 : Remove the Door Assembly.
Step 3 : Remove the Front Ornament Unit.
Step 4 : Remove the Front Panel Block.
Step 5 : Remove the SMPS P.C.B..
Step 6 : Use a tape to keep the centre switch (S643) pressed.
Step 7 : Place a Support Block to support the Front Panel
Block as shown.
Step 8 : Connect 14P FFC at the connector (CN941) on
Remote Sensor P.C.B..
Step 9 : Connect 5P wire at the connector (P944) on Remote
Sensor P.C.B..