EasyManua.ls Logo

Panasonic SF4C Series - Page 27

Panasonic SF4C Series
143 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SF4C Safety light curtain
2.4 Protection Area
19
When this device is used in the 'PSDI Mode', an appropriate safety distance S must be
calculated. For details, be sure to refer to the standards or regulations applicable in each region
or country.
EXAMPLE
Calculate the safety distance with the following values:
K: 2,000 mm/s
T
m
: 0.1s
T
SF4C
: 0,7ms
d: 25mm
With these values, the calculation is as follows:
S = K x T + C
= K x (T
m
+ T
SF4C
) + 8 x (d - 14)
= 2,000 x (0.1 + 0.007) + 8 x (25 - 14)
= 302
As 302 matches possibility 2 listed above, 302mm is the safety distance.
EXAMPLE
Calculate the safety distance with the following values:
K: 2,000mm/s
T
m
: 0.4s
T
SF4C
: 7ms
d: 25mm
With these values, the calculation is as follows:
S = K x T + C
= K x (T
m
+ T
SF4C
) + 8 x (d - 14)
= 2,000 x (0.4 + 0.007) + 8 x (25 - 14)
= 902
As 902 matches possibility 3 listed above, recalculate the safety distance with K' =
1,600mm/s.
S = K' x T + C
= K x (T
m
+ T
SF4C
) + 8 x (d - 14)
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
mailbox@sentronic.com
www.sentronic.com