Specifications and Dimensions
SF4C Safety light curtain
114
7.2 Common Specifications
Type Cable type Pigtailed type
Model No.
SF4C-H-
SF4C-H--J05
Sensing range 0,1 to 3m
Beam pitch 20mm
Detecting capability (Min.
object to be sensed)
Ø25mm opaque object
Effective aperture angle
(EAA)
±2.5° or less for sensing range exceeding 3m
(required by IEC 61496-2/UL 61496-2)
Supply voltage
24V DC
+10
-15
%. Ripple P-P 10% or less
Control output
(OSSD 1, OSSD 2)
PNP open-collector transistor/NPN open-collector transistor (switching type)
For PNP output: Max. source current 200mA
For NPN output: Max. sink current 200mA
Applied voltage: same as supply voltage (for PNP output: between the control output
(OSSD 1/2) and +V, for NPN output between the control output (OSSD 1/2) and 0V).
Residual voltage: 2.5V or less (For PNP output: source current 200mA, for NPN
output: sink current 200mA) (when using 10m length cable)
Leakage current: 200µA or less, when power supply is OFF
Maximum load capacity: 1µF (no load to maximum output current)
Load wiring resistance: 3Ω or less
Operation mode: ON when all beams are received, OFF when one or more beams
are interrupted (Note 1, 2), OFF when fault occurs in the sensor or the
synchronization signal error, too.
Protection circuit: Incorporated
Response time In normal operation: OFF: 7ms or less, ON: 90ms or less
Auxiliary output
(Non-safety output)
PNP open-collector transistor/NPN open-collector transistor (switching type)
For PNP output: Max. source current 100mA
For NPN output: Max. sink current 100mA
Applied voltage: same as supply voltage (for PNP output: between the auxiliary
output and +V, for NPN output between the auxiliary output and 0V)
Residual voltage: 2.5V or less (In case of selecting PNP output: source current
100mA, in case of selecting NPN output: sink current 100mA) (when using 10m
length cable)
Operation mode: When OSSDs are ON: OFF, When OSSDs are OFF: ON (factory
setting). This setting can be changed with the optional handy controller SFC-HC.
Protection circuit: Incorporated