Before Using this Device
SF4C Safety light curtain
36
2.6.2 PNP Output
C
C
C
C
C
C
C
C
A
A
B
B
B
B
B
B
B
B
B
B
B
B
E
E
E
E
F
F
F
F
D
D
D
D
*S1 *S2
*S2*S2 *S2 *S2
K1
K2
*S2
K1
K2
+
24V DC
%
-
+10
-15
(Brown) + V
(Pink) Test input / Reset input
(Pale purple) Interlock setting input
(Yellow) Override input
(Red) Muting lamp output
(Green / Black) Auxiliary output
(Gray) Safety input 1
(Gray / Black) Safety input 2
(Shield) Output polarity setting wire
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black)
Synchronization -
(Orange) Synchronization +
(Brown) + V
(Gray) Large multi-purpose
indicator input 1
(Sky-blue / White) Muting input 1
(Green) External device monitor input
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0V
(Gray / Black) Large multi-purpose
indicator input 2
(Sky-blue / Black) Muting input 2
Main circuit
Main circuit
Internal circuit Users’ circuit
Internal circuit Users’ circuit
Color code
Emitter
Receiver
Load
Terminal No. of
pigtailed type
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
mailbox@sentronic.com
www.sentronic.com
Produkte, Support und Service
SEN