SF4C Safety light curtain
30
5. Tighten the two hexagon-socket head bolts for beam-axis alignment M3
(length 5mm). The tightening torque should be 0.2N·m
Part A
Part B
6. Set the multifunctional bracket on the mounting surface using either two
hexagon head bolts (M6) or four hexagon head bolts (M4).
SF4C
SF4C
Hexagon head bolts
Hexagon head bolt
NOTE
SF4C-H28 and SF4C-H32 require the multifunctional intermediate supporting
bracket MS-SFC-4 (optional) (see page 31).