Before Using this Device
SF4C Safety light curtain
48
Feature Setting
Auxiliary output Not available
Wiring for PNP output
K1
K2
+
24V DC
%
-
+10
-15
SF4C
(Brown) + V
(Pink) Test input / Reset input
(Pale purple) Interlock setting input
(Yellow) Override input
(Red) Muting lamp output
(Green / Black) Auxiliary output
(Gray) Safety input 1
(Gray / Black)
Safety input 2
(Shield) Output polarity setting wire
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Brown) + V
(Gray) Large multi-purpose indicator input 1
(Sky-blue / White) Muting input 1
(Green) External device monitor input
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0V
(Gray / Black) Large multi-purpose indicator input 2
(Sky-blue / Black) Muting input 2
Gray cable
Emitter
Receiver
Gray cable
(with black line)
Safety contact
Symbols in the wiring diagram
Safety input
Short circuit (sink current: 5 to 10 mA), Source current 5 to 10mA: ON