PANDORA LIGHT PRO SERVICESECURITY SYSTEM
LED indicator.
Input the required number of digits (up to 4) and then press VALET button. The
system will confirm receiving of the secret validator code with long red flash of LED
indicator and will wait for confirmation of PIN-code.
Sublevel 11.3 - Confirmation of the PIN-code input:
Enter PIN-code again similarly to the procedure (LEVEL 11.2 – ENTERING PIN-CODE)
and press VALET button. The system will confirm correct PIN-code with red and
green flashes of LED indicator and will memorize PIN-code, and then the system
will proceed to programming mode awaiting level input. Incorrect confirmation is
indicated with long red flash of LED indicator, after that the system will return to
programming mode.
Level 12 – Calibrating of fuel level
To control fuel level, make connection and configure the settings:
• SettingisperformedviaPANDORA ALARMSTUDIO. «Use INP to control
fuel level» item should be enabled in the settings, the factory setting of this input
(input settings) must be unselected.
• Makeaconnectioninaccordancewiththe«Fuelcontrolinput»scheme.
To define the current fuel level, calibration should be performed at least by two
points. In some cases fuel level calibration should be performed by all specified points
(for more exact definition). To calibrate fuel level, enter the programming mode and
press VALET button 12 times.
Calibrating of fuel level:
Enter level 12 of programming, LED indicator will be lit red. Select the desired
sub-level. To adjust zero value, switch on the ignition and save the setting. The total
number of sublevels are 12 (listed in the table). Enter the number of the desired
sublevel by pressing VALET button (press the button a number of times equals to
theinputtingdigit;pausesbetweenpressesshouldnotexceed1second).
Run the engine no less than in 1 minute, then press VALET button – the data will
be sent to the base unit. To save, press button, pressing of button will be
P R O G R A M M I N G T H E S Y S T E M