10 Reference & Installation Manual
Figure 4.1: LCD Screen
4.6 Confidential Mode Timer
Section [007]
Section [007] determines the amount of time without action
before the keypad enters Confidential Mode. For more
information on Confidential Mode, refer to “Confidential Mode” on
page 9. The Confidential Mode Timer can be set from 005
seconds to 255 seconds. Default: 120 seconds.
4.7 Time Display Option
Section [003]: Option [8]
The LCD keypad comes with a time display option that can
display the date as year/month/day or as day/month/year.
Option [4] OFF = Normal Mode (default)
Option [4] ON = Confidential Mode
Option [5] OFF = LCD screen activated by entering an access
code (default)
Option [5] ON = LCD screen activated by pressing a button
Option [8] OFF = Date displayed as yy/mm/dd (default)
Option [8] ON = Date displayed as dd/mm/yy