Page #7 background imageLoading...
Page #7 background image
6
If the virtual input is set to follow its Virtual Input Timer, the entered value represents the amount of time that the virtual input will remain
open. To program the Virtual Input Timer, enter a 3-digit value from 000 to 255. Depending on the Virtual Input Base Time (see below), the
Virtual Input Timer will either be in seconds or minutes.
If option [5] is OFF, the value programmed for the Virtual Input Timer will be in seconds. If option [5] is ON, the Virtual Input Timer will be in
minutes. The following table lists the base time sections and their respective virtual inputs.
U = default setting
[790] 10 U close command N virtual input timer N close command or virtual input timer
[800] 11 U close command N virtual input timer N close command or virtual input timer
[810] 12 U close command N virtual input timer N close command or virtual input timer
[820] 13 U close command N virtual input timer N close command or virtual input timer
[830] 14 U close command N virtual input timer N close command or virtual input timer
[840] 15 U close command N virtual input timer N close command or virtual input timer
[850] 16 U close command N virtual input timer N close command or virtual input timer
Section [701]
Virtual Input Timers
Section Virtual Input Data Section Virtual Input Data
[701] 1 __/__/__ (000 to 255) x Base time [781] 9 __/__/__ (000 to 255) x Base time
[711] 2 __/__/__ (000 to 255) x Base time [791] 10 __/__/__ (000 to 255) x Base time
[721] 3 __/__/__ (000 to 255) x Base time [801] 11 __/__/__ (000 to 255) x Base time
[731] 4 __/__/__ (000 to 255) x Base time [811] 12 __/__/__ (000 to 255) x Base time
[741] 5 __/__/__ (000 to 255) x Base time [821] 13 __/__/__ (000 to 255) x Base time
[751] 6 __/__/__ (000 to 255) x Base time [831] 14 __/__/__ (000 to 255) x Base time
[761] 7 __/__/__ (000 to 255) x Base time [841] 15 __/__/__ (000 to 255) x Base time
[771] 8 __/__/__ (000 to 255) x Base time [851] 16 __/__/__ (000 to 255) x Base time
Section [700] - Option [5]
Virtual Input Base Time Selection
Section
Virtual
Input
[5] OFF [5] ON Section
Virtual
Input
[5] OFF [5] ON
[700] 1 U seconds N minutes [780] 9 U seconds N minutes
[710] 2 U seconds N minutes [790] 10 U seconds N minutes
[720] 3 U seconds N minutes [800] 11 U seconds N minutes
[730] 4 U seconds N minutes [810] 12 U seconds N minutes
[740] 5 U seconds N minutes [820] 13 U seconds N minutes
[750] 6 U seconds N minutes [830] 14 U seconds N minutes
[760] 7 U seconds N minutes [840] 15 U seconds N minutes
[770] 8 U seconds N minutes [850] 16
U seconds N minutes

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Digiplex EVO PRT3 and is the answer not in the manual?

Paradox Digiplex EVO PRT3 Specifications

General IconGeneral
BrandParadox
ModelDigiplex EVO PRT3
CategoryControl Unit
LanguageEnglish

Related product manuals