Programming Guide
SYSTEM TIMERS
Section # Decimal Value (000-255) Description Default Value
[050] ___/___/___ x10 msec. ZONE SPEED (ZONE 1) 600 msec.
[051] ___/___/___ x10 msec. ZONE SPEED (ZONE 2) 600 msec.
[052] ___/___/___ x10 msec. ZONE SPEED (ZONE 3) 600 msec.
[053] ___/___/___ x10 msec. ZONE SPEED (ZONE 4) 600 msec.
[054] ___/___/___ x10 msec. ZONE SPEED (ZONE 5) 600 msec.
[055] ___/___/___ X10 msec. ZONE SPEED (ZONE 6) 600 msec.
[056] ___/___/___ X10 msec. ZONE SPEED (ZONE 7) 600 msec.
[057] ___/___/___ X10 msec. ZONE SPEED (ZONE 8) 600 msec.
[058] ___/___/___ X10 msec. ZONE SPEED (ZONE 9) 600 msec.
[059] ___/___/___ x10 msec. ZONE SPEED (ZONE 10) 600 msec.
[060] ___/___/___ x10 msec. ZONE SPEED (ZONE 11) 600 msec.
[061] ___/___/___ x10 msec. ZONE SPEED (ZONE 12) 600 msec.
[062] ___/___/___ x10 msec. ZONE SPEED (ZONE 13) 600 msec.
[063] ___/___/___ x10 msec. ZONE SPEED (ZONE 14) 600 msec.
[064] ___/___/___ x10 msec. ZONE SPEED (ZONE 15) 600 msec.
[065] ___/___/___ x10 msec. ZONE SPEED (ZONE 16) 600 msec.
NOTE: If ATZ is enabled (section [132], key [5]), do not set the Zone Speed to less than 50msec. as this may cause false alarms.
[066] ___/___/___ seconds (000 = follow stop event) PGM1 TIMER 5 sec.
[067] ___/___/___ seconds (000 = follow stop event) PGM2 TIMER (1755/EX & 1758/EX ONLY) 5 sec.
[068] ___/___/___ seconds (000 = follow stop event) GLOBAL PGM TIMER (SEE PAGE 23 & 26) 5 sec.
[069] ___/___/___ seconds ENTRY DELAY 1 45 sec.
[070] ___/___/___ seconds ENTRY DELAY 2 45 sec.
[071] ___/___/___ seconds EXIT DELAY 1 30 sec.
[072] ___/___/___ seconds EXIT DELAY 2 30 sec.
[073] ___/___/___ minutes (000 = no bell on alarm) BELL CUT-OFF TIME - PARTITION 1 4 min.
[074] ___/___/___ minutes (000 = no bell on alarm) BELL CUT-OFF TIME - PARTITION 2 4 min.
[075] ___/___/___ x15 minutes (000 = disabled) NO MOVEMENT TIME - PARTITION 1 Disabled
[076] ___/___/___ x15 minutes (000 = disabled) NO MOVEMENT TIME - PARTITION 2 Disabled
[077] ___/___/___ seconds (min.= 10 sec.) ANS. MACHINE OVERRIDE DELAY Disabled
[078] ___/___/___ (000 = no answer; max. = 15 rings) NUMBER OF RINGS 8 rings
[079] ___/___/___ x2 sec. (min.= 32 sec.) TLM FAIL TIMER 32 sec.
[080] ___/___/___ seconds DELAY ALARM TRANSMISSION Disabled
[081] ___/___/___ (000 = 16; max. 16) MAXIMUM DIALING ATTEMPTS 8 attempts
[082] ___/___/___ seconds DELAY BETWEEN ATTEMPTS 20 sec.
[083] ___/___/___ seconds PAGER DELAY 5 sec.
[084] ___/___/___ seconds (min. 10 sec.) INTELLIZONE DELAY 48 sec.
[085] ___/___/___ seconds RECENT CLOSING DELAY No delay
[086] ___/___/___ minutes POWER FAILURE REPORT DELAY 15 min.
[087] ___/___/___ days (000 = disabled) AUTO TEST REPORT Disabled
[088] ___/___/___ (001-127 = +1 to +127 sec.) CLOCK ADJUST Disabled
(128-255 = -1 to -127 sec.)
[089] ___/___/___ (000 = Disabled; max. = 15) AUTO ZONE SHUTDOWN COUNTER 5
[090] ___/___/___ minutes (000 = disabled) RECYCLE ALARM DELAY Disabled
[091] ___/___/___ (000 = disabled) RECYCLE ALARM COUNTER Disabled
[110] ___/___:___/___Hrs (00-23) & Min. (00-59) AUTO TEST REPORT (TIME OF DAY) Disabled
[111] ___/___:___/___Hrs (00-23) & Min. (00-59) AUTO-ARM TIME - PARTITION 1 Disabled
[112] ___/___:___/___Hrs (00-23) & Min. (00-59) AUTO-ARM TIME - PARTITION 2 Disabled

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra 1728 and is the answer not in the manual?

Paradox Spectra 1728 Specifications

General IconGeneral
BrandParadox
ModelSpectra 1728
CategoryControl Panel
LanguageEnglish

Related product manuals