INSTANT ARMING
After Stay Arming the system and during its Exit Delay, press and hold the [STAY] button for 3 seconds. You should hear a
"CONFIRMATION BEEP". This will switch all armed zones to Instant zones.
If you have access to both partitions:
To Instant Arm one partition, press [STAY] + [ACCESS CODE] + [SELECT PARTITION] + [CLEAR] + press & hold [STAY]
To Instant Arm both partitions, press [STAY] + [ACCESS CODE] + [1] + [2] + press & hold [STAY]
FORCE ARMING
Force Arming allows users to rapidly arm the system, without having to wait for all zones in the system to be closed. Force Arming
is commonly used when a motion detector is protecting the area occupied by a keypad. Therefore, when arming the system, if the
motion detector is set as a Force Zone, the control panel will ignore the zone and allow users to arm the system even if the zone
is open. Any open Force Zones at the time of arming will be considered "deactivated" by the control panel. If during this period a
"deactivated" zone is closed, the control panel will revert that zone to "active" status, hence, will generate an alarm if breached.
If you make a mistake, the keypad will emit a "REJECTION BEEP". When correctly Force Armed, the appropriate "ARM"
indication will appear and the Exit Delay will be initiated. Please note that Force Arming can also be activated using One-
Touch Force Arming. Also note that the Access Code must have the Force Arming Option enabled.
MANUAL BYPASS PROGRAMMING
Manual Bypass Programming allows users to program the alarm system to ignore ("deactivate") specified zones the next
time the system is armed. Please note that Fire Zones can not be bypassed and that Manual Bypass Programming can also
be activated using One-Touch Bypass Programming.
*If you have access to both partitions, press the button corresponding to the desired
partition. The Access Code must have the Bypass Programming Option enabled.
How Do I Force Arm?
1) All zones in the desired partition (except Force Zones) must be closed.
2) Press the [FORCE] button
3) Key in a valid [ACCESS CODE]
IF YOU HAVE ACCESS TO BOTH PARTITIONS:
4) Press the button corresponding to the partition you wish to Arm. To
Arm both partitions, press the [1] key then after the confirmation beep
press the [2] key.
How do I Program Bypass Entries?
1) Press the [BYP] button.
2) Key in a valid [ACCESS CODE]*
3) Select one or more [ZONES] you wish to bypass
4) Once you have entered the desired bypass entries, press the [ENTER]
button to accept these entries.