SYSTEM OPTIONS
Bold = Default Setting
SECTION [127]: General Options
Option OFF ON
[1] Partitioning l Disabled l Enabled
[2] Access Code Length l 6-digits l 4-digits
[3] Keypad Audible Trouble Warning l Disabled l Enabled
[4] Lock System Master Code l Disabled l Enabled
[5] Battery Charge Current l 350mA l 700mA
[6] User Code 048 is a Duress Code l Disabled l Enabled
[7] Alarm Relay follows (1755/EX & 1758/EX only) l Bell Output l Global PGM
[8] Normal State of PGM1 l Normally Closed (N.C.) l Normally Open
SECTION [128]: General Options
Option OFF ON
[1] Panic 1: Keys [1] & [3] l Disabled l Enabled
[2] Panic 2: Keys [4] & [6] l Disabled l Enabled
[3] Panic 3: Keys [7] & [9] l Disabled l Enabled
[4] Panic 1: Silent or Audible l Silent l Audible
[5] Panic 2: Silent or Audible l Silent l Audible
[6] Panic 3: Silent or Fire l Silent l Fire
[7] Keypad 1 Tamper Supervision l Disabled l Enabled
[8] Keypad 2 Tamper Supervision l Disabled l Enabled
SECTION [129]: General Options
Option OFF ON
[1] PGM2 Output Activation Option* l Steady l Pulse (flash)
[2] PGM2 Pulse Once Every 30sec. If System Armed* l Disabled l Enabled
[3] PGM2 Pulse On Arm, Twice On Disarm* l Disabled l Enabled
[4] SPC-ZX4/8 Zone Expansion Module Supervision l Disabled l Enabled
[5] SPC-319 Wireless Module Supervision l Disabled l Enabled
[6] SPC-319 Wireless Module Low Battery Super. l Disabled l Enabled
[7] Siren Driver* on Bell Output l Disabled l Enabled
[8] Normal State of PGM2 l Normally Closed (N.C.) l Normally Open
*1755, 1755EX, 1758 and 1758EX only
SECTION [130]: Arming/Disarming Options
Option OFF ON
[1] One-Touch Regular Arming l Disabled l Enabled
[2] One-Touch Stay Arming l Disabled l Enabled
[3] One-Touch Force Arming l Disabled l Enabled
[4] One-Touch Bypass Programming l Disabled l Enabled
[5] Restrict Arming on Battery Failure l Disabled l Enabled
[6] Restrict Arming on Tamper Trouble l Disabled l Enabled
[7] Bell Squawk on Arm/Disarm with Keypad l Disabled l Enabled
[8] Beep on Exit Delay l Disabled l Enabled