SIGNAL STRENGTH DISPLAY
Enter the section (see next page) corresponding to the desired Expansion Input, then activate the transmitter by opening/
closing the zone or by pressing the tamper switch. NOTE: after entering the section, ignore the first reading as it won’t be
accurate. LED Keypad: Lights numbered from one to eight will illuminate. An average reading of 3 and up is acceptable.
LCD Keypad: One to eight characters will appear on the screen. An average reading of 3 characters and up is acceptable.
Section # Description
[631] Display Signal Strength of Expansion Input 1 - Section [601]
[632] Display Signal Strength of Expansion Input 2 - Section [602]
[633] Display Signal Strength of Expansion Input 3 - Section [603]
[634] Display Signal Strength of Expansion Input 4 - Section [604]
[635] Display Signal Strength of Expansion Input 5 - Section [605]
[636] Display Signal Strength of Expansion Input 6 - Section [606]
[637] Display Signal Strength of Expansion Input 7 - Section [607]
[638] Display Signal Strength of Expansion Input 8 - Section [608]
LIBERATOR MODULE (SPC-319) RESET
[640] PRESS [ENTER] TO CONFIRM. WILL RESET THE LIBERATOR MODULE’S SECTIONS [601] TO [624] TO DEFAULT VALUES.