14 Programming Guide
Zone Timers (MG Series)
Zone Timers (SP Series)
Wireless Transmitter Signal Strength
To view the wireless transmitter signal strength, press the wireless transmitter’s anti-tamper switch while in the respective
section.
Section MG5000 MG5050 Data Description (Default 060)
[041] Zone 1 (Z1): (Z1): ____/____/____ (000 to 255) x 10ms Hardwire Zone 1 Speed
[042] Zone 2 (Z2): (Z2): ____/____/____ (000 to 255) x 10ms Hardwire Zone 2 Speed
[043] Zone 3 (Z1 with ATZ): (Z3): ____/____/____ (000 to 255) x 10ms Hardwire Zone 3 Speed
[044] Zone 4 (Z2 with ATZ): (Z4): ____/____/____ (000 to 255) x 10ms Hardwire Zone 4 Speed
[045] Zone 5 (Z5): ____/____/____ (000 to 255) x 10ms Hardwire Zone 5 Speed
[046] Zone 6 (Z1 with ATZ): ____/____/____ (000 to 255) x 10ms Hardwire Zone 6 Speed
[047] Zone 7 (Z2 with ATZ): ____/____/____ (000 to 255) x 10ms Hardwire Zone 7 Speed
[048] Zone 8 (Z3 with ATZ): ____/____/____ (000 to 255) x 10ms Hardwire Zone 8 Speed
[049] Zone 9 (Z4 with ATZ): ____/____/____ (000 to 255) x 10ms Hardwire Zone 9 Speed
[050] Zone 10 (Z5 with ATZ): ____/____/____ (000 to 255) x 10ms Hardwire Zone 10 Speed
[051] Zone 11 ____/____/____ (000 to 255) x 10ms Hardwire Zone 11 Speed
[052] Zone 12 ____/____/____ (000 to 255) x 10ms Hardwire Zone 12 Speed
[053] Zone 13 ____/____/____ (000 to 255) x 10ms Hardwire Zone 13 Speed
[054] Zone 14 ____/____/____ (000 to 255) x 10ms Hardwire Zone 14 Speed
[055] Zone 15 ____/____/____ (000 to 255) x 10ms Hardwire Zone 15 Speed
[056] Zone 16 ____/____/____ (000 to 255) x 10ms Hardwire Zone 16 Speed
Section SP5500 SP6000 SP7000* Data Description (Default 060)
[041] Zone 1 (Z1): (Z1): (Z1): ____/____/____ (000 to 255) x 10ms Hardwire Zone 1 Speed
[042] Zone 2 (Z2): (Z2): (Z2): ____/____/____ (000 to 255) x 10ms Hardwire Zone 2 Speed
[043] Zone 3 (Z3): (Z3): (Z3): ____/____/____ (000 to 255) x 10ms Hardwire Zone 3 Speed
[044] Zone 4 (Z4): (Z4): (Z4): ____/____/____ (000 to 255) x 10ms Hardwire Zone 4 Speed
[045] Zone 5 (Z5): (Z5): (Z5): ____/____/____ (000 to 255) x 10ms Hardwire Zone 5 Speed
[046] Zone 6 (Z1 with ATZ): (Z6): (Z6): ____/____/____ (000 to 255) x 10ms Hardwire Zone 6 Speed
[047] Zone 7 (Z2 with ATZ): (Z7): (Z7): ____/____/____ (000 to 255) x 10ms Hardwire Zone 7 Speed
[048] Zone 8 (Z3 with ATZ): (Z8): (Z8): ____/____/____ (000 to 255) x 10ms Hardwire Zone 8 Speed
[049] Zone 9 (Z4 with ATZ): (Z1 with ATZ): (Z9): ____/____/____ (000 to 255) x 10ms Hardwire Zone 9 Speed
[050] Zone 10 (Z5 with ATZ): (Z2 with ATZ): (Z10): ____/____/____ (000 to 255) x 10ms Hardwire Zone 10 Speed
[051] Zone 11 (Z3 with ATZ): (Z11): ____/____/____ (000 to 255) x 10ms Hardwire Zone 11 Speed
[052] Zone 12 (Z4 with ATZ): (Z12): ____/____/____ (000 to 255) x 10ms Hardwire Zone 12 Speed
[053] Zone 13 (Z5 with ATZ): (Z13): ____/____/____ (000 to 255) x 10ms Hardwire Zone 13 Speed
[054] Zone 14 (Z6 with ATZ): (Z14): ____/____/____ (000 to 255) x 10ms Hardwire Zone 14 Speed
[055] Zone 15 (Z7 with ATZ): (Z15): ____/____/____ (000 to 255) x 10ms Hardwire Zone 15 Speed
[056] Zone 16 (Z8 with ATZ): (Z16): ____/____/____ (000 to 255) x 10ms Hardwire Zone 16 Speed
* SP7000: For zones 17-32 (ATZ), the zone timer is set at 60 seconds.
Section Section Section Section
[101] Zone 1 [109] Zone 9 [117] Zone 17 [125] Zone 25
[102] Zone 2 [110] Zone 10 [118] Zone 18 [126] Zone 26
[103] Zone 3 [111] Zone 11 [119] Zone 19 [127] Zone 27
[104] Zone 4 [112] Zone 12 [120] Zone 20 [128] Zone 28
[105] Zone 5 [113] Zone 13 [121] Zone 21 [129] Zone 29
[106] Zone 6 [114] Zone 14 [122] Zone 22 [130] Zone 30
[107] Zone 7 [115] Zone 15 [123] Zone 23 [131] Zone 31
[108] Zone 8 [116] Zone 16 [124] Zone 24 [132] Zone 32
Signal Strength Indicator
8 to 10 / 3 beeps = Best signal 5 to 7 / 2 beeps = Average signal 1 to 4 / 1 beep = Weak signal (Relocate)