Associated Equipment 7-10
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
890CS Dynamic Braking Resistors - Europe
These resistor sets (complete with cover) are designed for stopping the system at rated power.
They are rated for 10 seconds in a 100 seconds duty cycle.
IMPORTANT The continuous rating of the quoted resistor is not to be exceeded under repetitive loading conditions.
Frame
Size
Drive
Amps
(A)
Drive
Rating
(kW)
Brake
Volts
(V)
Peak
Amps
(A)
Minimum
Ohms
(
)
Cressall
Part
Number
Dimensions
L x W x H
(mm)
Resistance
(
)
Rated
Amps
(A)
Rated
Power
(W)
208/230 Vac
B 32 7.5 390 20 19.5 HP1-24R 505 x 138 x 135.5 24 8 1500
B 54 15 390 40 9.8 HP1-12R 505 x 138 x 135.5 12 11 1500
D
108
30
390
75
5.2
HP1-5R6
505 x 138 x 135.5
5.6
16
1500
D 162 45 390 100 3.9 HP2-4R7 505 x 138 x 135.5 4.7 25 3000
380/415 Vac
B
32
15
770
20
38.5
HP1-47R
505 x 138 x 135.5
47
5.6
1500
B 54 30 770 40 19.3 HP1-24R 505 x 138 x 135.5 24 8 1500
D
108
60
770
75
10.3
HP2-12R
505 x 233 x 135.5
12
16
3000
D 162 90 770 100 7.7 HP3-8R2 505 x 327 x 135.5 8.2 23 4500
500 Vac
B
32
18
830
20
41.5
HP1-47R
505 x 138 x 135.5
47
5.6
1500
B 54 37 830 40 20.8 HP1-24R 505 x 138 x 135.5 24 8 1500
D
108
75
830
75
11.1
HP2-12R
505 x 233 x 135.5
12
16
3000
D 162 110 830 100 8.3 HP3-10R 505 x 327 x 135.5 10 21 4500