Operating the Drive
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
3% Choke
Drive
Frame
Size
Motor
Power
Input
Voltage
Choke Inductance Currents
(kW/Hp) (V)
(
H)
50Hz 1kHz 2.5kHz Sum
E 22/30 230 CO468341U030 177 72.50 1.87 0.00 73
F 45/60 230 CO468341U055 92 139.57 3.60 0.00 140
F 90/150 400 CO468325U110 137 163.13 4.21 0.00 164
G 180/300 400 CO468325U220 68 327.17 8.45 0.00 328
H 280/450 400 CO468325U315 48 471.28 12.17 0.00 472
J 315/500 400 CO468325U355 42 534.72 13.81 0.00 535
Note: Lower values for THD of current can be achieved by adding extra line impedance.