890CS & 890CD Common Bus Units 4-4
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Enclosure/Environmental Information
The information here will help you to specify the enclosure to house the 890(s).
Operating Temperature
0°C to 45°C (32°F to 113°F)
Product Enclosure Rating IP20 - UL (c-UL) Open Type (North America/Canada) Type 1
Suitable for cubicle mount only
Cubicle Installation The 890 must be installed to EN60204 Standard in the cubicle. For
USA, the cubicle shall meet the requirements of UL50.
Cubicle Rating Cubicle to provide the following attenuation to radiated emissions:
Attenuation to RF in
spectrum 30-1000MHz
EN61800-3
Category C3
NONE
EN61800-3
Category C1 Restricted Distribution
EN61000-6-3
10db
EN61800-3
Category C1 Unrestricted Distribution
EN61000-6-4
20db