EasyManua.ls Logo

Parker ac890 - Page 314

Parker ac890
711 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Keypad Menus 10-12
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
DIAGNOSTIC MENU
890CD Common Bus Drive & 890SD Standalone Drive
PREF
6511 Display
6901 Display
99.06
BRAKING
Range: FALSE / TRUE
A read-only parameter indicating the state of the dynamic brake switch.
(Refer to the DYNAMIC BRAKING function
block)
73.04
DRIVE FREQUENCY
Range: —.xx Hz
The drive output frequency in Hertz.
(Refer to the PATTERN GEN function block)
97.05
ACTIVE WORD 1
Range: 0000 to FFFF
Indicates which trips are currently active. These parameters are a coded representation of the trip status.
(Refer to the TRIPS STATUS function block)
97.06
ACTIVE WORD 2
Range: 0000 to FFFF
Indicates which trips are currently active. These parameters are a coded representation of the trip status.
(Refer to the TRIPS STATUS function block)
97.09
FIRST TRIP
Range: Enumerated - refer to block
From when a trip occurs until that trip is reset, this parameter indicates the trip source. When several trips have
occurred, this parameter indicates the first one that was detected.
(Refer to the TRIPS STATUS function block)

Table of Contents

Other manuals for Parker ac890

Related product manuals