10-25 Keypad Menus
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
QUICK SETUP MENU
890CD Common Bus Drive & 890SD Standalone Drive
(induction
motor
only)
* MOTOR
CONNECTION
This parameter contains the motor nameplate
connection.
1= STAR
71.01
PULSE ENC VOLTS
The voltage output from the encoder feedback
card.
10 to 20V 5.0
71.02
ENCODER LINES
The number of lines must be set to match the
type of encoder being used. Incorrect setting
of this parameter will result in an erroneous
speed measurement.
250 to 32767 2048
71.03
ENCODER INVERT
When TRUE, changes the sign of the
measured speed and the direction of the
position count.
0=FALSE
1=TRUE
0
80.01
AUTOTUNE
ENABLE
Determines whether the Autotune sequence is
operational or not. The Autotune sequence is
operational when set to TRUE and the drive is
run
0=FALSE
1=TRUE
0
AUTOTUNE MODE
Selects the Autotune operating mode.
1 : ROTATING
2 : SPD LOOP
ROTATING
3 : SPD LOOP
STATIONARY