EasyManua.ls Logo

Parker ac890 - Page 337

Parker ac890
711 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11-6 Trips & Fault Finding
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
6511
Keypad
Display
6901
Keypad
Display
Description Possible Reason for Trip
IN 2 INPUT 2 BREAK I/O TRIPS:: INPUT 2
BREAK has gone True
Check configuration to determine source of signal
STLL MOTOR STALLED The motor has stalled (not
rotating)
Motor loading too great
Current limit level is set too low
Stall trip duration is set too low
Fixed or auto boost levels are set too high
IT INVERSE TIME
The inverse time current limit is active: motor loading
is too great; fixed or auto boost levels are too high
(Full Load Current = 150% for 60 seconds)
DB R BRAKE RESISTOR External dynamic braking
resistor has been overloaded
Trying to decelerate a large inertia load too quickly or
too often
DB S BRAKE SWITCH Internal dynamic braking
switch has been overloaded
Trying to decelerate a large inertia load too quickly or
too often
DISP OP STATION Keypad has been
disconnected from drive
whilst drive is running in
local control
Keypad accidentally disconnected from drive

Table of Contents

Other manuals for Parker ac890

Related product manuals