EasyManua.ls Logo

Parker ac890 - Page 532

Parker ac890
711 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming D-136
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Parameter Descriptions
STATUS
PREF: 114.14
Default: 4
Range: See below
This diagnostic indicates the status of operation of the drive.
Enumerated Value : Status
0 : INACTIVE
1 : SYNCHRONIZING
2 : SYNCHRONIZED
3 : SUPPLY FREQ HIGH
4 : SUPPLY FREQ LOW
5 : SYNCH FAILED
INACTIVE : Indicates when the 4Q drive is not running
SYNCHRONIZING : Indic
ates during mains synchronisation period (first 100ms after Run command)
SYNCHRONIZED : Indicates successful synchronisation is complete
SUPPLY FREQ HIGH : Indicates 4Q drive output frequency is greater than 70Hz. This is a fault condition
SUPPLY FREQ LOW
: Indicates the 4Q drive output frequency is less than 40Hz. This is a fault condition
SYNCH FAILED : Indicates the 4Q drive has failed to synchronise on to the mains supply. This is a fault condition

Table of Contents

Other manuals for Parker ac890

Related product manuals