Programming D-204
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
2PREF Name Block Type Range Default ro\rw Notes
45.03 SCALING OPERATOR
MENU 13
ENUM 0 : NONE
1 : DISPLAY SCALE 1
2 : DISPLAY SCALE 2
3 : DISPLAY SCALE 3
4 : DISPLAY SCALE 4
NONE rw
45.04 READ ONLY OPERATOR
MENU 13
BOOL 0 : FALSE
1 : TRUE
FALSE rw
45.05 IGNORE
PASSWORD
OPERATOR
MENU 13
BOOL 0 : FALSE
1 : TRUE
FALSE rw
46.01 PARAMETER OPERATOR
MENU 14
PREF 00.00 to B8.01 0 rw
46.02 NAME OPERATOR
MENU 14
STRING max length is 16 chars rw
46.03 SCALING OPERATOR
MENU 14
ENUM 0 : NONE
1 : DISPLAY SCALE 1
2 : DISPLAY SCALE 2
3 : DISPLAY SCALE 3
4 : DISPLAY SCALE 4
NONE rw
46.04 READ ONLY OPERATOR
MENU 14
BOOL 0 : FALSE
1 : TRUE
FALSE rw
46.05 IGNORE
PASSWORD
OPERATOR
MENU 14
BOOL 0 : FALSE
1 : TRUE
FALSE rw
47.01 PARAMETER OPERATOR
MENU 15
PREF 00.00 to B8.01 0 rw
47.02 NAME OPERATOR
MENU 15
STRING max length is 16 chars rw
47.03 SCALING OPERATOR
MENU 15
ENUM 0 : NONE
1 : DISPLAY SCALE 1
2 : DISPLAY SCALE 2
3 : DISPLAY SCALE 3
4 : DISPLAY SCALE 4
NONE rw

Table of Contents