Programming D-212
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
2PREF Name Block Type Range Default ro\rw Notes
64.01 PARAMETER OPERATOR
MENU 32
PREF 00.00 to B8.01 0 rw
64.02 NAME OPERATOR
MENU 32
STRING max length is 16 chars rw
64.03 SCALING OPERATOR
MENU 32
ENUM 0 : NONE
1 : DISPLAY SCALE 1
2 : DISPLAY SCALE 2
3 : DISPLAY SCALE 3
4 : DISPLAY SCALE 4
NONE rw
64.04 READ ONLY OPERATOR
MENU 32
BOOL 0 : FALSE
1 : TRUE
FALSE rw
64.05 IGNORE
PASSWORD
OPERATOR
MENU 32
BOOL 0 : FALSE
1 : TRUE
FALSE rw
65.01 DECIMAL PLACE DISPLAY SCALE 1 ENUM 0 : DEFAULT
1 : X.XXXX
2 : X.XXX
3 : X.XX
4 : X.X
5 : X.
DEFAULT rw
65.02 FORMULA DISPLAY SCALE 1 ENUM 0 : A/B * X + C
1 : A/B * (X+C)
2 : A/(B * X) + C
3 : A/(B * (X+C))
A/B * X + C rw
65.03 COEFFICIENT A DISPLAY SCALE 1 REAL -32768.0000 to
32767.0000
1.0000 rw
65.04 COEFFICIENT B DISPLAY SCALE 1 REAL -32768.0000 to
32767.0000
1.0000 rw
65.05 COEFFICIENT C DISPLAY SCALE 1 REAL -32768.0000 to
32767.0000
0.0000 rw
65.06 HIGH LIMIT DISPLAY SCALE 1 REAL -32768.0000 to
32767.0000
0.0000 rw