D-247
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
2PREF Name Block Type Range Default ro\rw Notes
128.03 NETWORK MODE CONTROLNET ENUM 0 : INVALID
1 : POWER UP
2 : CHECK FOR CABLE
3 : WAITING 2 ROGUE
4 : CHK 4 MODERATOR
5 : I'M ALIVE
6 : ATTACHED
7 : FORCED LISTEN
8 : DUPLICATE NODE
INVALID ro Output
128.04 CONNECTED CONTROLNET BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
128.05 SERIAL NUMBER CONTROLNET INT _ 0 ro Output
128.06 FAULT CONTROLNET BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
128.07 DIAGNOSTIC CONTROLNET WORD 0000 to FFFF 0000 ro Output
128.09 CNET STATE CONTROLNET ENUM 0 : NONE
1 : FAULT
2 : INITIALISE
3 : VM CONFIGURE
4 : WAIT 2 ATTACH
5 : WAIT 2 CONNECT
6 : RUNNING
NONE ro Output
129.01 MODE COMMS PORT ENUM 0 : AUTOMATIC
1 : 6511 OP STATION
2 : 6901 OP STATION
3 : TS8000 HMI
4 : RTNX HMI
AUTOMATIC rw
130.01 BAUDRATE DEVICENET ENUM 0 : 125K
1 : 250K
2 : 500K
3 : INVALID
125K ro Output
130.02 MAC ID DEVICENET INT _ 0 ro Output