2PREF Name Block Type Range Default ro\rw Notes
133.04 SPEED MAX RESOLVER INT 0 to 2147483647 10000 rw 2
133.05 ACCURACY RESOLVER REAL 0.00 to 60.00 20.00 rw 2
133.06 CARRIER
VOLTAGE
RESOLVER REAL 1.00 to 10.00 V 7.00 V rw 2
133.07 CURRENT RESOLVER REAL 0.000 to 0.100 A 0.046 A rw 2
133.08 INERTIA RESOLVER REAL 10.00 to
32768.00Kg.cm2
24.00Kg.cm2 rw 2
133.11 POSITION SET UP RESOLVER REAL -180.00 to 180.00 deg 0.00 deg rw
133.15 RESOLVER POS
OUT
RESOLVER REAL _.xxxx 0.0000 ro Output
133.16 TRIP RESOLVER BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
133.17 INIT DONE RESOLVER BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
133.18 REVERSE CNT DIR RESOLVER BOOL 0 : FALSE
1 : TRUE
FALSE rw 2
133.19 SPEED FILTER RESOLVER REAL 10.00 to 1000.00 Hz 100.00 Hz rw
133.20 PHASE SHIFT RESOLVER REAL 0.00 to 180.00 deg 0.00 deg rw
133.21 TRIP SELECTION RESOLVER ENUM 0 : HARD AND SOFT
1 : HARD
2 : SOFT
SOFT rw
133.26 RESET LINE
COUNT
RESOLVER BOOL 0 : FALSE
1 : TRUE
FALSE rw
133.27 LINE COUNT X4 RESOLVER INT _ 0 ro Output
133.28 PULLEYBELT
RATIO
RESOLVER INT 1 to 100 1 rw 2
134.01 MANUFACTURER MOTOR PMAC 1 STRING max length is 16 chars rw 2
134.02 MODEL MOTOR PMAC 1 STRING max length is 16 chars rw 2