E-25 Technical Specifications
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Electrical Ratings: 890SD Frame C, 230V
Input currents are listed at 230Vac at 50Hz. Suitable for use in a circuit capable of delivering not more than 5000 rms Symmetrical
Amperes. Motor power, input current and output current must not be exceeded under steady state operating conditions.
Model Number
890SD-232240C
(890SD/2/0024C)
890SD-232300C
(890SD/2/0030C)
Nominal Supply Voltage
230Vac
230Vac
230Vac
230Vac
Motor Power
5.5kW
7.5Hp
7.5kW
10Hp
Input Bridge I
2
t
A
2
s
1100
1100
External Maximum Power Rating
W
1800
2500
External Minimum Resistor Rating
15
12
Vector Mode
Input Current
A
31
40
Output Current @ 3kHz
A
24
30
Power Loss @ 3kHz
W
240
300
Output Current @ 6kHz
A
20
24
Power Loss @ 6kHz
W
270
360
Output Overload Motoring
150% overload for 60 seconds (all vector modes) 180% for 1s (V/Hz mode)
Servo Mode
Input Current
A
31
40
Output Current @ 4kHz
A
24
30
Power Loss @ 4kHz
W
250
315
Output Current @ 8kHz
A
20
24
Power Loss @ 8kHz
W
290
370
Output Overload Motoring
200% overload for 4 seconds (PMAC mode)