E-37 Technical Specifications
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Cooling Fans
The forced-vent cooling of the drive is achieved by 1, or in some cases 2, 24VDC fans.
890 Product Frame Size
Drive Voltage Rating
Drive Current Rating
Air Flow
(m
3
/hr / cfm)
(V)
(A)
CS
B
208 - 500
32
46 / 27
CS
B
208 - 500
54
46 / 27
CS
D
208 - 500
108
46 / 27
CS
D
208 - 500
108
204 / 120
CS
D
208 - 500
162
46 / 27
CS
D
208 - 500
162
204 / 120
SD / CD
B
208 - 240
3
46 / 27
SD / CD
B
208 - 240
5
46 / 27
SD / CD
B
208 - 240
7
46 / 27
SD / CD
B
208 - 240
11
46 / 27
CD
B
208 - 240
16.5
46 / 27
SD
B
208 - 240
16.5
56 / 33
SD / CD
B
380 - 500
2
46 / 27
SD / CD
B
380 - 500
3
46 / 27
SD / CD
B
380 - 500
4
46 / 27
SD / CD
B
380 - 500
6
46 / 27
SD / CD
B
380 - 500
10
46 / 27
SD / CD
B
380 - 500
12
46 / 27
CD
B
380 - 500
16
46 / 27
SD
B
380 - 500
16
56 / 33
CD
B
380 - 500
16 - 30% more peak
46 / 27
SD
B
380 - 500
16 - 30% more peak
56 / 33