EasyManua.ls Logo

Parker GVI Series - 13 Product Specifications; General; Current and Power Output Ratings

Parker GVI Series
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Specifications
GVI Product Manual: Frames C, D & E
54 192-300300N1 GVI Frames C, D & E 2019-9
13. Product Specifications
13.1 General
Description
Value
Supported motor types
Permanent Magnet Synchronous AC motors
Switching frequency
4, 8, 12, 16 kHz
Operating stator current frequency
0-599 Hz
Control modes
Speed (rpm), Torque (Nm), Current (ARMS) or Voltage
(VDC)
Communication
CAN
Connector
AMP SEAL 35-pin
Operating temperature
-40 °C to + 55 °C (-40 °F to +131 °F)
Storage temperature
-40 °C to +70 °C (-40 °F to +158 °F), ambient humidity of
95 %
13.2 Current and power output ratings
GVI model Nominal
DC
supply
voltage
[V DC]
Rated
current
(S2 2
min)
[ARMS]*
Rated
current
(S2 1 h)
[ARMS]**
Rated
power
(S2
2min)
[kVA]*
Rated
power
(S2 1h)
[kVA]**
Frame C
GVI-C024-0350
24
350
150
10.3
4.4
GVI-C048-0280
48
280
120
16.5
7.1
Frame D
GVI-D024-0550
24
550
275
16.2
8.1
GVI-D048-0450
48
450
225
26.5
13.2
GVI-D048-0550
48
550
275
32.3
16.2
GVI-D080-0230
80
230
115
22.5
11.3
GVI-D080-0350
80
350
175
34.3
17.1
GVI-D080-0400
80
400
200
39.2
19.6
Frame E
GVI-E048-0700
48
700
350
41.2
20.6
GVI-E080-0500
80
500
250
49.0
24.5
GVI-E080-0700
80
700
350
68.6
34.3
* 2 minute rating at 8 kHz switching frequency and 25ºC ambient temperature.
** 1 h rating at 8 kHz switching frequency, 40ºC ambient temperature, and 6 m/s air flow through finned heat sink.

Table of Contents

Related product manuals