Environmental testing & standards appliance 
61  192-300300N1 GVI Frames C, D & E 2019-9 
13.6.4.  Mechanical tests 
Random vibration accelerated life 
The drive was in operation during the test 
2 500 positive and 2 500 negative half sine pulses with 
acceleration of 25 g, pulse length 6 ms for all 3 octagonal 
axis, tested as described in EN60068-2-27 Test Ea 
5 positive and 5 negative half sine pulses with 
acceleration of 50 g, pulse length 6 ms for all 3 octagonal 
axis, tested as described in EN 60068-2-27 test Ea 
13.6.5.  EMC 
According to EN12895, Industrial Trucks (radiated 
emission test EN 55022 class B) 
Immunity 27 -1 000 MHz 20V/m 
ESD 8 kV contact 15 kV air discharge 
Electrical fast transient /burst 
13.6.6.  Isolation 
B- terminal to heat sink 
500 Vac (50 Hz/60 Hz) 
B- terminal to heat sink