EasyManua.ls Logo

Parker GVI Series - Mechanical Tests; Emc; Isolation

Parker GVI Series
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parker EME
Environmental testing & standards appliance
61 192-300300N1 GVI Frames C, D & E 2019-9
13.6.4. Mechanical tests
Subject
Standard
Random vibration accelerated life
EN 60068-2-64 test Fh
Frequency
Acceleration PSD
[Hz]
[g2/Hz]
5
0.02
8
0.025
14
0.2
25
0.05
100
0.05
200
0.04
250
0.03
275
0.075
350
0.02
500
0.02
Total g RMS
4.5
Duration
50 h in each direction
The drive was in operation during the test
Bump 25 G
2 500 positive and 2 500 negative half sine pulses with
acceleration of 25 g, pulse length 6 ms for all 3 octagonal
axis, tested as described in EN60068-2-27 Test Ea
Shock 50 G
5 positive and 5 negative half sine pulses with
acceleration of 50 g, pulse length 6 ms for all 3 octagonal
axis, tested as described in EN 60068-2-27 test Ea
13.6.5. EMC
Subject
Standard
Emission
According to EN12895, Industrial Trucks (radiated
emission test EN 55022 class B)
Immunity 27 -1 000 MHz 20V/m
EN 61000-4-3
ESD 8 kV contact 15 kV air discharge
EN 61000-4-2
Electrical fast transient /burst
EN61000-4-4 level 2
13.6.6. Isolation
Subject
Standard
GVI 24-48 V
B- terminal to heat sink
500 Vac (50 Hz/60 Hz)
According to EN 1175-1
GVI 80 V
B- terminal to heat sink
1 200 Vac (50 Hz/60 Hz)
According to EN 1175-1

Table of Contents