GVI Product Manual: Frames C, D & E
60 192-300300N1 GVI Frames C, D & E 2019-9
Heat sink type (GVI
size in parenthesis)
Figure 34 Width (W) and length (L) of heat sinks
13.5.3. Surface requirement
For motor controller with flat heat sink, the mounting surface in the vehicle shall fulfill this requirement for full
rating according to chapter 13.2.
Ra 1.6
Table 16 Roughness and flatness requirement
13.6 Environmental testing & standards appliance
13.6.1. General
IP65 Test IEC 60529 (with mating connector installed)
EC declaration of incorporation of partly completed
machinery according to EN1175-1
13.6.2. Temperature
Cold storage -40 °C, 16 hours
Dry heat storage +85 °C, 16 hours
Cold operation -40 °C, 16 hours
Dry heat operation 65 °C, 16 hours
Change of temperature -40 °C to 65 °C, 20 cycles
13.6.3. Humidity
Humidity steady-state 85 % Rh 85 °C, 500 hours
Composite temperature/humidity cyclic test -10 °C to +65 °C