Product Specifications
GVI Product Manual: Frames C, D & E
60 192-300300N1 GVI Frames C, D & E 2019-9
Heat sink type (GVI
size in parenthesis)
H x W x L
[mm]
GVI Frame C:
12.5 x 200 x 150
GVI Frame D:
23 x 200 x 150
GVI Frame E:
23 x 200 x 235
Figure 34 Width (W) and length (L) of heat sinks
13.5.3. Surface requirement
For motor controller with flat heat sink, the mounting surface in the vehicle shall fulfill this requirement for full
rating according to chapter 13.2.
Motor Controller
Model
Tolerance
Roughness
All C Models
0.1/200x150 mm
Ra 1.6
Table 16 Roughness and flatness requirement
13.6 Environmental testing & standards appliance
13.6.1. General
Subject
Standard
Protection class
IP65 Test IEC 60529 (with mating connector installed)
Standard
EC declaration of incorporation of partly completed
machinery according to EN1175-1
13.6.2. Temperature
Subject
Standard
Cold storage -40 °C, 16 hours
IEC 60068-2-1 test Ad
Dry heat storage +85 °C, 16 hours
IEC 60068-2-2 test Bd
Cold operation -40 °C, 16 hours
IEC 60068-2-1 test Ad
Dry heat operation 65 °C, 16 hours
IEC 60068-2-2 test Bd
Change of temperature -40 °C to 65 °C, 20 cycles
IEC 60068-2-14 test Na
13.6.3. Humidity
Subject
Standard
Humidity steady-state 85 % Rh 85 °C, 500 hours
IEC 60068-2-78 test Cab
Composite temperature/humidity cyclic test -10 °C to +65 °C
IEC 60068-2-38 test Z/AD

Table of Contents

Related product manuals