DDeessccrriippttiioonn PPoossssiibbllee RReeaassoonn ffoorr TTrriipp
RSLV RESOLVER ERROR See function block description
♦ Resolver disconnected
♦ Resolver incorrectly wired
♦ Resolver not compatible with resolver feedback
option board
♦ Resolver length cable too long
♦ Incorrect Resolver Function Block settings
MI2T I2T MOTOR TRIP See function block description
♦ Motor is undersized
STO SAFE TORQUE OFF -
♦ The safe torque off feature has been activated. See
Chapter 6, STO Trip Annunciation.
DCFG DRIVE CONFIG ERR Drive configuration error
♦ The configuration defined in DRIVE CONFIG
doesn't match the actual drive configuration.
CT1 Reservoir Over T Reservoir Over Temp
CT2 Low Oil Levl Oil Level Low
♦ HAS Reservoir exceed 158F and Trip on Temp set in
config
♦ HAS Reservoir level low and Trip on Low Level
set in config