DDIIAAGGNNOOSSTTIICC MMEENNUU
PPRREEFF 66551111 DDiissppllaayy 66990011 DDiissppllaayy
70.10 TTOORRQQUUEE FFEEEEDDBBAACCKK
RRaannggee:: —.xx %
The estimated motor torque, as a percentage of rated motor torque.
(Refer to the FEEDBACKS function block)
70.11 FFIIEELLDD FFEEEEDDBBAACCKK
RRaannggee:: —.xx %
A value of 100% indicates the motor is operating at rated magnetic flux (field).
(Refer to the FEEDBACKS function block)
70.12 MMOOTTOORR CCUURRRREENNTT %%
RRaannggee:: —.xx %
This diagnostic contains the level of rms line current being drawn from the drive and is seen
as a % of the MOTOR CURRENT parameter setting in the MOTOR INDUCTION function
block.
(Refer to the FEEDBACKS function block)
70.13 MMOOTTOORR CCUURRRREENNTT AA
RRaannggee:: —.xx A
This diagnostic contains the level of rms line current being drawn from the drive.
(Refer to the FEEDBACKS function block)
70.02 DDCC LLIINNKK VVOOLLTTSS
RRaannggee:: —.xx V
The internal dc voltage tested across the DC link capacitors.
(Refer to the FEEDBACKS function block)
70.03 TTEERRMMIINNAALL VVOOLLTTSS
RRaannggee:: —.xx V
This shows the rms voltage, between phases, applied by the drive to the motor terminals.
(Refer to the FEEDBACKS function block)
86
wwwwww..ppaarrkkeerr..ccoomm/