66551111
KKeeyyppaadd
DDiissppllaayy
66990011
KKeeyyppaadd
DDiissppllaayy
DDeessccrriippttiioonn PPoossssiibbllee RReeaassoonn ffoorr TTrriipp
IN 1 INPUT 1 BREAK I/O TRIPS:: INPUT 1
BREAK has gone True
♦ Check configuration to determine source of signal
IN 2 INPUT 2 BREAK I/O TRIPS:: INPUT 2
BREAK has gone True
♦ Check configuration to determine source of signal
STLL MOTOR STALLED The motor has stalled (not
rotating)
♦ Motor loading too great
♦ Current limit level is set too low
♦ Stall trip duration is set too low
♦ Fixed or auto boost levels are set too high
IT INVERSE TIME
♦ The inverse time current limit is active: motor loading
is too great; fixed or auto boost levels are too high
(Full Load Current = 150% for 60 seconds)
DB R BRAKE RESISTOR External dynamic braking
resistor has been overloaded
♦ Trying to decelerate a large inertia load too quickly or
too often
DB S BRAKE SWITCH Internal dynamic braking
switch has been overloaded
♦ Trying to decelerate a large inertia load too quickly or
too often
96
wwwwww..ppaarrkkeerr..ccoomm/
cylinder