Trip Table
66551111
KKeeyyppaadd
DDiissppllaayy
66990011
KKeeyyppaadd
DDiissppllaayy
DDeessccrriippttiioonn PPoossssiibbllee RReeaassoonn ffoorr TTrriipp
IN 1 INPUT 1 BREAK I/O TRIPS:: INPUT 1
BREAK has gone True
Check configuration to determine source of signal
IN 2 INPUT 2 BREAK I/O TRIPS:: INPUT 2
BREAK has gone True
Check configuration to determine source of signal
STLL MOTOR STALLED The motor has stalled (not
rotating)
Motor loading too great
Current limit level is set too low
Stall trip duration is set too low
Fixed or auto boost levels are set too high
IT INVERSE TIME
The inverse time current limit is active: motor loading
is too great; fixed or auto boost levels are too high
(Full Load Current = 150% for 60 seconds)
DB R BRAKE RESISTOR External dynamic braking
resistor has been overloaded
Trying to decelerate a large inertia load too quickly or
too often
DB S BRAKE SWITCH Internal dynamic braking
switch has been overloaded
Trying to decelerate a large inertia load too quickly or
too often