Hydraulic and Electrohydraulic Actuators
HAS Series Analog Drives Manual
95
Parker Hannifin Corporation
Cylinder Division
Des Plaines, Illinois USA
www.parker.com/cylinder
Catalog HY08-4005-M3
WARNING: This product can expose you to chemicals including Lead and Lead Compounds which are known to the State of
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PROP 65 WARNING
Trip Table
66551111
KKeeyyppaadd
DDiissppllaayy
66990011
KKeeyyppaadd
DDiissppllaayy
DDeessccrriippttiioonn PPoossssiibbllee RReeaassoonn ffoorr TTrriipp
DISP OP STATION
Keypad has been
disconnected from drive whilst
drive is running in local control
♦ Keypad accidentally disconnected from drive
SCI COMMS BREAK
♦ COMMS BREAK parameter set to True (refer to I/O
TRIPS menu at level 3)
CNTC CONTACTOR FBK
♦ The CONTACTOR CLOSED input in the
SEQUENCING LOGIC function block remained
FALSE after a run command was issued
SPD SPEED FEEDBACK
♦ SPEED ERROR > 50.00% for 10 seconds
AOT AMBIENT TEMP
♦ The ambient temperature in the drive is too high
97
wwwwww..ppaarrkkeerr..ccoomm/
cylinder
PPaarrkkeerr HHaannnniiffiinn CCoorrppoorraattiioonn
Cylinder Division
Des Plaines, Illinois