Trip Table
66551111
KKeeyyppaadd
DDiissppllaayy
66990011
KKeeyyppaadd
DDiissppllaayy
DDeessccrriippttiioonn PPoossssiibbllee RReeaassoonn ffoorr TTrriipp
OT MOTOR
OVERTEMP
The motor temperature is
too high
Excessive load
Motor voltage rating incorrect
FIXED BOOST and/or AUTO BOOST set too high
Prolonged operation of the motor at low speed
without forced cooling
Check setting of INVERT THERMIST parameter in I/
O TRIPS menu at level 3.
BBrreeaakk iinn mmoottoorr tthheerrmmiissttoorr ccoonnnneeccttiioonn
A24SC 24V FAILURE The 24V customer output
has fallen below 17V
24V customer output is short
circuited Excessive loading