REGULATORY COMPLIANCE UL AND CE
IPA Hardware Installation Guide 95
You must install a mains power line filter on both the Motor power mains and Control power mains if they are to
be used independently. Use the following tables to determine the correct filter for your specific application.
Control Power
Control power is 1 Ampere, maximum. Any of the following filters works with all models of the IPA drive.
Control Power Filter Selection
Filter
Manufacturer
FN670-3/06
Schaffner
6EP1 (160937-5)
Corcom
10EP1 (160937-7)
1,
Corcom
FN2070-10/06
Schaffner
1. Available from Parker: 10 Amp filterpart number 47-016140-01
Mains Motor Power
Mains Motor Power Filter Selection
Filter
Continuous Current (Amps)
IPA04-HC
IPA15-HC
6EP1 (160937-5)
1
5 at 240 VAC
10EP1 (160937-7)
1, 3
8 at 240 VAC
x
x
FN2070-10/06
2
10 at 240 VAC
x
x
FN2070-12/06
12 at 240 VAC
x
x
FN2070-16/06
2, 3
16 at 240 VAC
x
x
Product with applicable mains filter denoted by “x
1. Corcom (a division of Tyco Electronics)
2. Schaffner
3. Available from Parker: 10 Amp filterpart number 47-016140-01
Install transient suppressors. You must install varistors or other voltage surge limiting devices in order to meet
the requirements of IEC 61000-4-5. Place a Littelfuse V275LA2ØC, or an equivalent varistor, from line to line and
from lines to earth before the mains filter, as shown in the EMC Installation drawings. (Intersil, General Electric, and
Littelfuse manufacture equivalent varistors.)
Use an EMC-ready motor or a motor that has demonstrated acceptable EMC performance. Motors
with shielded cabling or pipe thread style cabling options allow the easiest integration into machines required to
bear the CE mark for EMC.
Note: Motors may bear the CE mark. This mark indicates the motor meets the requirements of
construction and safetynot EMC compliance.